Rockwell Automation 1715-AENTR EtherNet/IP Adapter
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device. The following versions of Rockwell Automation 1715-AENTR EtherNet/IP Adapter are affected: 1715-AENTR EtherNet/IP Adapter <=3.003 (CVE-2026-10577) CVSS Vendor Equipment Vulnerabilities v3 10 Rockwell Automation Rockwell Automation 1715-AENTR EtherNet/IP Adapter Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Energy, Water and Wastewater, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-10577 A security issue exists within the 1715-AENTR EtherNet/IP Adapter. The affected product exposes a network-accessible debug port that does not enforce proper privilege controls, allowing unauthenticated remote access to intrusive command-line interface (CLI) commands. If exploited, a threat actor could read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device. View CVE Details Affected Products Rockwell Automation 1715-AENTR EtherNet/IP Adapter Vendor: Rockwell Automation Product Version: Rockwell Automation 1715-AENTR EtherNet/IP Adapter: <=3.003 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends that users update to 1715-AENTR EtherNet/IP Adapter version 3.011 and later. Mitigation Rockwell Automation recommends users of the affected software who are not able to upgrade to one of the corrected versions should use their security best practices. https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, see the Rockwell Automation security advisory SD1785 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1785.html Mitigation If you have any questions regarding this security issue and how to mitigate it,contact Rockwell Automation for help. https://www.rockwellautomation.com/en-us/company/about-us/contact-us.html Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H 4.0 10 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-14 Date Revision Summary 2026-07-14 1 Initial Republication of Rockwell Automation security advisory SD1785. Legal Notice and Terms of Use
Related articles
New North Korean campaign uses fake coding interviews to steal developer credentials
DPRK-aligned hackers hid malware inside SVG flag images to backdoor developer job interview coding tests. Not one antivirus vendor caught it.
Abbott probes two cyber incidents amid extortion claims
Abbott Laboratories is investigating two separate cybersecurity incidents after confirming unauthorized access to internal legacy Exact Sciences systems in its Cancer Diagnostics business, while also investigating a separate claim that attackers breached its LabCentral portal and stole company data.
HollowByte DDoS flaw bloats OpenSSL server memory with 11-byte payload
A vulnerability dubbed HollowByte allows unauthenticated attackers to trigger a denial-of-service (DoS) condition on OpenSSL servers with a malicious payload of just 11 bytes.